Fluke 179/61-KIT Offers
Created for industrial, HVAC, and facility maintenance.
The Fluke 179 True-rms digital multimeter has the features needed to find most electrical and HVAC problems. Simple to use with significant improvements like True-rms, frequency, capacitance, temperature and min-max record. The Fluke 179 has more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view.
The Fluke 179/61 Combo Kit includes the Fluke 179 True-rms multimeter with a built-in thermometer to troubleshoot electrical and electromechanical problems plus a laser guided, non-contact infrared thermometer for measuring rotating or energized equipment, packed in a durable carrying case.
Check the features and specifications using the tabs above.
Electrical safety
All inputs are protected to measurement CAT III 1000 V and CAT IV 600V. This meter can withstand transient impulses in excess of 8000 V to help protect you from arc blasts resulting from surges and spikes.
Available as kits such as:
Fluke 179/EDA2 Electronics Multimeter and Deluxe Accessory Combo Kit or
Fluke 179/1AC-II Electrician's Multimeter and Voltage Tester Combo Kit or
Fluke 179/TPAK Digital Multimeter & ToolPak™ Combo Kit
Also available with no temperature as
Fluke 177 or as
Fluke 175
Combo Kit includes:
Fluke 179/61-KIT Specifications
| Specifications |
| Voltage DC |
| Accuracy* | ± (0.09%+2) | | Max. Resolution | 0.1 mV | | Maximum | 1000 V | |
| Accuracy* |
± (0.09%+2) |
| Max. Resolution |
0.1 mV |
| Maximum |
1000 V |
| Voltage AC |
| Accuracy* | ± (1.0%+3) | | Max. Resolution | 0.1 mV | | Maximum | 1000 V | |
| Accuracy* |
± (1.0%+3) |
| Max. Resolution |
0.1 mV |
| Maximum |
1000 V |
| Current DC |
| Accuracy* | ± (1.0%+3) | | Max. Resolution | 0.01 mA | | Maximum | 10 A | |
| Accuracy* |
± (1.0%+3) |
| Max. Resolution |
0.01 mA |
| Maximum |
10 A |
| Current AC |
| Accuracy* | ± (1.5%+3) | | Max. Resolution | 0.01 mA | | Maximum | 10 A | |
| Accuracy* |
± (1.5%+3) |
| Max. Resolution |
0.01 mA |
| Maximum |
10 A |
| Resistance |
| Accuracy* | ± (0.9%+1) | | Max. Resolution | 0.1 Ω | | Maximum | 50 MΩ | |
| Accuracy* |
± (0.9%+1) |
| Max. Resolution |
0.1 Ω |
| Maximum |
50 MΩ |
| Capacitance |
| Accuracy* | ± (1.2%+2) | | Max. Resolution | 1 nF | | Maximum | 10,000 μF | |
| Accuracy* |
± (1.2%+2) |
| Max. Resolution |
1 nF |
| Maximum |
10,000 µF |
| Frequency |
| Accuracy* | ± (0.1%+1) | | Max. Resolution | 0.01 Hz | | Maximum | 100 kHz | |
| Accuracy* |
± (0.1%+1) |
| Max. Resolution |
0.01 Hz |
| Maximum |
100 kHz |
| Temperature |
| Accuracy* | ± (1.0%+10) | | Max. Resolution | 0.1°C | | Range | -40°C/400°C | |
| Accuracy* |
± (1.0%+10) |
| Max. Resolution |
0.1°C |
| Range |
-40°C/400°C |
| Note |
| * | Accuracies are best accuracies for each function |
|
| * |
Accuracies are best accuracies for each function |
| Environmental Specifications |
| Operating temperature |
|
| |
-10°C to +50°C |
| Storage temperature |
|
| |
-30°C to +60°C |
| Humidity (Without Condensation) |
| 0% - 90% (0°C - 35°C) |
| 0% - 70% (35°C -50°C) | |
| |
0% - 90% (0°C - 35°C) |
| |
0% - 70% (35°C -50°C) |
| Safety Specifications |
| Overvoltage category |
| EN 61010-1 to 1000 V CAT III. |
| EN 61010-1 to 600 V CAT IV. | |
| |
EN 61010-1 to 1000 V CAT III. |
| |
EN 61010-1 to 600 V CAT IV. |
| Agency Approvals |
|
| |
UL, CSA, T�V listed and VDE Pending |
| Mechanical & General Specifications |
| Size |
|
| |
43 x 90 x 185 mm |
| Weight |
|
| |
420 g |
| Warranty |
|
| |
Lifetime |
| Battery life |
| Alkaline | ~200 hours typical, without backlight |
|
| Alkaline |
~200 hours typical, without backlight |
Click here for complete specifications on the Fluke 179/61-KIT
What's included with the Fluke 179/61-KIT