Model: 3000 FC HVAC Kit | Order No: 3000FC-HVAC
The Fluke Connect HVAC/R Kit includes the 3000 FC Multimeter, AC current clamp module. temperature module and accessories.
The Fluke Connect enabled HVAC kit includes all the modules an HVAC professional will need daily on the job.
The 3000 FC HVAC Kit includes several modules and accessories including the Fluke 3000 FC Multimeter, a3000 FC Current Clamp, T3000 FC K-Type Temperature Module, and other accessories.
The multimeter at the core of the Fluke Connect suite of tools.
The Fluke 3000FC Digital Multimeter is part of the Fluke Connect system of test tools, communicating with the new Fluke connect mobile app available for Android™ or iOS smart phones. The 3000FC wireless digital multimeter functions as the mobile hub, displaying readings from up to three module tools simultaneously from 20 meters away. Fluke Connect modules also give you the flexibility to build your wireless test tool system how you want it.
By seeing multiple measurements at the same time, troubleshooters can see cause and effect, interactions between inputs/outputs or other measurement points, simultaneously and remotely.For those who need to see more than 3 measurements at a time, the addition of the PC3000 FC Adapter allows for up to 10 modules to be viewed at any time on a PC.
The Fluke 3000FC meets measurement category 1000V CAT III and Category IV 600V safety standards.
Fluke Connect enabled Clamp Meter Module
A fully functional True-RMS current clamp meter that wirelessly relays measurements to other Fluke Connect™ enabled master units.
This True RMS clamp meter is capable of taking measurements up to 400A AC, features an inrush function, and is capable of logging up to 65,000 readings. You'll be able to use the a3000 FC as a standalone unit or as part of the Fluke Connect suite of tools.
The Fluke T3000FC features a measurement range of -200°C to 1372°C with a resolution of 0.1°C. The battery life on the T3000FC will reach up to 400 hours of use, allowing you to focus on the job rather than your battery life.
With communications ranges of up to 20m in open unobstructed air, 6.5m through obstructed sheetrock walls, and up to 3.5m through with obstructed concrete or steel walls. The T3000FC will allow you to work from a safe distance while still receiving all the data you need to do the job.
AC Voltage | |
Range | 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | 1.0 % + 3 from 45 Hz to 500 Hz 2.0 % + 3 from 500 Hz to 1 kHz |
DC Voltage | |
Range | 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | 0.09 % + 2 0.09 % + 2 0.15 % + 2 |
Continuity | |
Range | 600 Ω |
Resolution | 1 Ω |
Accuracy | Meter beeps at <25 Ω, beeper detects opens or shorts of 250 µs or longer. |
Resistance | |
Range | 600.0 Ω 6.000 kΩ 60.00 kΩ 60.00 kΩ 600.0 kΩ 50.00 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | 0.5 % + 2 @ 600.0 Ω 0.5% + 1 from 6.000 to 600.0 kΩ 1.5 % + 3 @ 50.00 MΩ |
Diode Test | |
Range | 2.000 V |
Resolution | 0.001 V |
Accuracy | 1 % + 2 |
Capacitance | |
Range | 1000 nF 10.00 µF 100.0 µF 9999 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy | 1.2 % + 2 from 1000 nF to 100 µF 10 % Typical @ 9999 µF |
AC and DC Current | |
Range | 60.00 mA 400.0 mA |
Resolution | 0.01 mA 0.1 mA |
Accuracy | AC: 1.5 % + 3 from 45 Hz to 1 kHz DC: 0.5 % + 3 |
Frequency | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | 0.1 % + 1 |
Min/Max Recording | |
Accuracy | DC Functions: ±12 counts for changes >350 ms in duration AC Functions: ±40 counts for changes >900 ms in duration |
General Specifications | |
Maximum Voltage Between Any Terminal and Earth Ground | 1000 V DC or AC RMS |
Fuse Protection from A Inputs | 0.44 A (44/100 A, 440 mA) 1000 V FAST Fuse Fluke Specified Part Only |
Display (LCD) | Update Rate: 4/sec Volts, Amps, Ohms: 6000 Counts Frequency: 10,000 Counts Capacitance: 1,000 Counts |
Battery Type | 3 x AA Alkaline Batteries, NEDA 15A IEC LR6 |
Battery Life | 250 Hours Minimum |
RF Communications | 2.4 GHZ ISM Band |
RF Communication Range | Open Air, Unobstructed: Up to 20m Obstructed, Sheetrock Wall: Up to 6.5m Obstructed, Concrete Wall, or Steel Electrical Enclosure: Up to 3.5m |
Temperature | Operating: -10 to 50°C Storage: -40 to 60°C |
Temperature Coefficient | 0.1 x (Specified Accuracy)/°C (<18°C or >28°C) |
Relative Humidity | 0 to 90% (0 to 35°C) 0 to 75% (35 to 40°C) 0 to 45% (40 to 50°C) |
Altitude | Operating: 2,000 m Storage: 12,000 m |
Electromagnetic Compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety Compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd Edition CAN/CSA-C22.2 No 61010-1-12: 3rd Edition UL 61010-1: 3rd Edition IEC/EN 61010-1:2010 |
Certifications | CSA, FCC, CE |
Ingress Protection (IP) Rating | IP54 |
Pollution Degree | 2 |
Dimensions | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14") |
Weight | 340 g (12 oz) |
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Fluke 3000 FC HVAC/R Kit.