Model: 115-NIST | Order No: 115/EFSP-NIST
Ideal for electrical and electronic testing applications, this True RMS meter also comes equipped with simple, one-handed operation and compact design.
The compact, general purpose troubleshooting tool for field service technicians
Ideal for general purpose electrical and electronic test requirements, this True RMS digital multimeter also provides simple, one-handed operation and compact design for field service technicians. This tool measures the True RMS voltage as well as currents with 6000 count, resistance, continuity, frequency, and capacitance for quick verifications. Additionally, this digital multimeter is independently tested for safe use in CAT III 600V environments.
This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Features
Applications
DC Millivolts | |
Range | 600 mV |
Resolution | 0.1 mV |
Accuracy | 0.5% + 2 |
DC Volts | |
Range | 6 V 60 V 600 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | 0.5% + 2 |
Auto Volts | |
Range | 600 V |
Resolution | 0.1 V |
Accuracy | 2.0% + 3 (dc 45 to 500 Hz) 4.0% + 3 (500 Hz to 1kHz) |
AC Millivolts1 True RMS | |
Range | 600 mV |
Resolution | 0.1 mV |
Accuracy | 1.0% + 3 (dc 45 to 500 Hz) 2.0% + 3 (500 Hz to 1kHz) |
AC Volts1 True RMS | |
Range | 6 V 60 V 600 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | 1.0% + 3 (dc 45 to 500 Hz) 2.0% + 3 (500 Hz to 1kHz) |
Continuity | |
Range | 600 Ω |
Resolution | 1 Ω |
Accuracy | Beeper on <20 off> 250; detects opens or shorts of 500 µs or longer |
Ohms | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 40 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | 0.9% + 2 0.9% + 1 5% + 2 |
Diode Test | |
Range | 2 V |
Resolution | 0.001 V |
Accuracy | 0.9% + 2 |
Capacitance | |
Range | 1000 nF 10 µF 100 µF 9999 µF 100 to 1000 µF >1000 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy | 1.9% + 2 1.9% + 2 5% + 20 |
Lo-Z capacitance | |
Range | 1 nF to 500 µF |
Accuracy | 10% + 2 typical |
AC Amps True RMS (45 to 500 Hz) | |
Range | 6 A 10 A 20 A overload for 30 seconds max |
Resolution | 0.001 A 0.01 A |
Accuracy | 1.5% + 3 |
DC Amps | |
Range | 6 A 10 A 20 A overload for 30 seconds max |
Resolution | 0.001 A 0.01 A |
Accuracy | 1.0% + 3 |
Hz (V or A Input)2 | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | 0.1% + 2 |
Click on a category to view a selection of compatible accessories with the Fluke 115-NIST True RMS Digital Multimeter, .