Model: 117/323-KIT
Comes equipped with a True RMS clamp meter, this kit is built around a non-contact voltage meter. The multimeter performs non-contact voltage detection and helps prevent false readings caused by ghost voltage. Additionally, the clamp meter features True RMS measurements and optimized ergonomics.
The digital multimeter includes integrated non-contact voltage detection to help get the job done faster
Ideal for applications such as commercial buildings, hospitals, and schools, this multimeter comes equipped with True-RMS. This instrument helps prevent false readings caused by ghost voltage due to integrated non-contact voltage detection, Auto Volts, and LoZ functions. Additionally, this tool comes supplied with min/max/average readings and measures frequency, capacitance, and an easy-to-use interface.
Engineered and tested with your safety on the job in mind
Tested for safe use in CAT III 600 V environments and designed in several features to make it easier and faster for you to get the measurements you need.
Features
Applications
Fluke 323 True RMS Clamp Meter
Delivers rugged and reliable performance and includes True RMS measurements, optimized ergonomics, and large display which makes it ideal for troubleshooting. This clamp meter is part of the 320 series and is built to perform in the toughest environments, and provides you with noise-free and reliable results. Its slim, compact size and rugged design makes it well suited for measuring currents up to 400 A in tight cable compartments. Use it to verify the presence of load current, AC voltage, continuity of circuits, switches, fuses, and contacts.
Features
Applications
Fluke TL175 TwistGuard Test Leads Set
Features
Fluke TPAK ToolPak Magnetic Meter Hanger
Features
DC millivolts | |
Range | 600.0 mV |
Resolution | 0.1 mV |
Accuracy | ±0.5% of reading + 2 counts |
DC Volts | |
Range | 6.000 V 60.00 V 600.0 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | ±0.5% of reading + 2 counts |
Auto Volts | |
Range | 600 mV |
Resolution | 0.1 mV |
Accuracy | 2% + 3 (dc. 45 to 500 Hz) 4% + 3 (500 Hz to 1 kHz) |
AC millivolts True RMS | |
Range | 600.0 mV |
Resolution | 0.1 mV |
Accuracy | 45 to 500 Hz: ±1.0% of reading + 3 counts 500 Hz to 1 kHz: ±2.0% of reading + 3 counts |
AC Volts True RMS | |
Range | 6.000 V 60.00 V 600.0 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | 45 to 500 Hz: ±1.0% of reading + 3 counts 500 Hz to 1 kHz: ±2.0% of reading + 3 counts |
Continuity | |
Range | 600 Ω |
Resolution | 1 Ω |
Accuracy | Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer |
Ohms | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 40 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | 0.9% + 1 |
Diode Test | |
Range | 2 V |
Resolution | 0.001 V |
Accuracy | 0.9% + 2 |
Capacitance | |
Range | 1000 nF 10 µF 100 µF 9999 µF 100 to 1000 µF >1000 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy | 1.9% + 2 1.9% + 2 5% + 20 |
Lo-Z Capacitance | |
Range | 1 nF to 500 µF |
Accuracy | 10% + 2 typical |
AC Amps True RMS (45 to 500 Hz) | |
Range | 6.000 A 10.00 A 20 A overload for 30 seconds maximum |
Resolution | 0.001 A 0.01 A |
Accuracy | ±1.5% of reading + 3 counts |
AC µAmps True RMS (45 Hz to 1 kHz) | |
Range | 600.0 µA |
Resolution | 0.1 µA |
Accuracy | ±1.5% of readings + 3 counts (±2.5% of readings + 3 counts >500 Hz) |
DC Amps | |
Range | 6.000 A 10.00 A 20 A overload for 30 seconds maximum |
Resolution | 0.001 A 0.01 A |
Accuracy | ±1.0% of readings + 3 counts |
Hz (V or A input) | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | ±0.1% of readings + 2 counts |
General Specifications | |
Maximum Voltage Between Any Terminal and Earth Ground | 600 V |
Surge Protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Fuse for A Input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) |
Display | Digital: 6000 counts, updates 4/sec |
Bar Graph | 33 segments, updates 32/sec |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Battery | 9 V alkaline, NEDA 1604A/IEC 6LR61 |
Battery Life | 400 hours typical, without backlight |
With integrated VoltAlert technology, AutoVolts and LoZ functions, this digital multimeter performs non-contact voltage detection and helps prevent false readings caused by ghost voltage. Features True RMS capabilities for accurate measurements on non-linear loads and a large white LED backlight to use in poorly lit areas.
Designed to perform in the toughest environments and provides you with reliable results, this True RMS clamp meter allows access in tight areas due to its slim, compact size. It is ideal for identifying the presence of load current, AC voltage, and continuity of circuits, switches, fuses, and contacts.
By simply twisting the test lead the user can change the exposed probe tip length from 19 mm to 4 mm (0.75 inch to 0.16 inch).
Hang your meter in a variety of ways for convenient hands-free operation. Attaches to most Fluke meters.
Click on a category to view a selection of compatible accessories with the Fluke 117/323-KIT Electricians Multimeter Combo Kit.