Model: FLUKE-87V/PRV240 | Order No: 87V/PRV240
The industrial multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high-energy, and high-altitude locations while the proving unit easily and safely verifies test tools.
Identifies complex signal problems fast
Provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment. On top of that, this industrial multimeter effectively performs in loud, high energy, and high altitude locations. Features a low pass filter which supports precise frequency measurements on VFDs and acquires intermittents as quickly as 250 µS.
Use this multimeter to measure AC currents up to 10 A directly. Also, features a built-in thermometer that enables you to take temperature readings without having to carry a separate instrument and more. Plus, comes with a bright, two-level backlit display which allows you to see the results better in dim light.
Correctly measure pulse-width modulated motor drive signal
Takes the guesswork out of drive system troubleshooting. Includes a unique function for accurately measuring noisy at the VFD and at the motor terminals. Special shielding blocks high frequency, high-energy noise generated by large drive systems.
Electrical safety
All the inputs on this industrial multimeter are updated to the third and CAT III, 1000 V. They are designed to withstand spikes in excess of 8 V.
Features
Applications
Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.
Features
Test Before Touch
Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of "Test Before Touch" (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.
Designed for safety and compliance
Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.
Applications
Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.
Features
Test Before Touch
Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of "Test Before Touch" (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.
Designed for safety and compliance
Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.
Applications
Fluke 87V | |
Voltage DC | Max voltage: 1000 V Accuracy: ±(0.05% + 1) Maximum resolution: 10 µV |
Voltage AC | Max voltage: 1000 V Accuracy: ±(0.7% + 2) True RMS AC bandwidth: 20 kHz with low pass filter; 3 db @ 1 kHz Maximum resolution: 0.1 mV |
Current DC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(0.2% + 2) Maximum resolution: 0.01 µA |
Current AC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(1.0% + 2) True RMS Maximum resolution: 0.1 µA |
Resistance | Maximum resistance: 50 MΩ Accuracy: ±(0.2% + 1) Maximum resolution: 0.1 Ω |
Capacitance | Maximum capacitance: 9999 µF Accuracy: ±(1% + 2) Maximum resolution: 0.01 nF |
Frequency | Maximum frequency: 200 kHz Accuracy: ±(0.005% + 1) Maximum resolution: 0.01 Hz |
Temperature | Operating: -4 to 131°F (-20 to 55°C) Storage: -40 to 140°F (-40 to 60°C) |
Operating Altitude | 6561' (2000 m) |
Dimensions | 7.9 x 3.9 x 2.05" (201 x 98 x 52 mm) |
Weight | 0.8 lb (355 g) |
PRV240 | |
Output Voltage: 240 V AC RMS or DC | ±10 % ≥1 MΩ |
Output Voltage: LoZ >3 kΩ load | 60 V AC typical; 50 V AC RMS minimum |
LED Power Indicator | Turns on when output voltage is present |
Battery | 4 x AA Alkaline batteries NEDA (24 A IEC LR03) |
Battery Life | 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load |
Operating Temperature | -10 to +50°C |
Operating Humidity | 0 % to 90 % (0 to 35°C) |
Operating Altitude | 2000 m |
Safety | IEC61010-1, IEC61010-2-030 |
Certification | CSA-CUS, CE |
Dimensions | 11.7 x 7.4 x 2.8 cm (4.6 x 2.9 x 1.1") |
Weight | 8 oz (0.23 kg) includes batteries |
Solve problems fast and deliver accurate and advanced troubleshooting capabilities that can handle complex signals. Additionally, this industrial multimeter with temperature is ideal for troubleshooting motor drives, plant automation, power distribution, and electromechanical equipment.
The portable, pocket-sized, battery-powered voltage source is unique because it sources stable AC/DC voltages for both LoZ and HiZ instruments. Works with multimeters, clamp meters, voltage testers, and two pole testers.