Fluke 744V20 Specifications

Measurement Accuracy
Voltage DC
110.000 mV 0.025%+0.015% *
1.10000 V 0.025%+0.005% *
11.0000 V 0.025%+0.005% *
110.000 V 0.05%+0.005% *
300.00 V 0.05%+0.005% *
Voltage AC
20 to 40 Hz 2% + 10
40 to 500 Hz 0.5% + 5
500 to 1 kHz 2% + 10
1 kHz to 5 kHz 10% + 20
Ranges 1.1000, 11.000, 110.00, 300V
Current DC
30.000 mA 0.01% + 0.015% *
110.00 mA 0.01% + 0.015% *
Resistance
11.000 Ω 0.05% + 50 mΩ
110.00 Ω 0.05% + 50 mΩ
1.1000 kΩ 0.05% + 500 mΩ
11.000 kΩ 0.1% + 10 Ω
Frequency
1.00 to 109.99 Hz 0.05 Hz
110.0 to 1099.9 Hz 0.5 Hz
1.100 to 10.999 kHz 5 Hz
11.00 to 50.00 kHz 50 Hz
Pressure
Accuracy from 0.025% of range using any of 29 pressure modules.
Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
(for detailed specifications refer to pressure modules in options and accessories)
Note
* (% of reading + % of full scale)

Source Accuracy
Voltage DC
110.000 mV 0.01%+0.005% *
1.10000 V 0.01%+0.005% *
15.0000 V 0.01%+0.005% *
Current DC
22.000 mA (Source) 0.01%+ 0.015% *
22.000 mA (Simulate) 0.02% + 0.03% *
Resistance
11.000 Ω 0.01% + 20 mΩ
110.00 Ω 0.01% + 40 mΩ
1.1000 kΩ 0.02% + 500 mΩ
11.000 kΩ 0.03% + 5Ω
Frequency
0.00 to 10.99 Hz 0.01 Hz
11.00 to 109.99 Hz 0.1 Hz
110.0 to 1099.9 Hz 0.1 Hz
1100 to 21999 Hz 2 Hz
22.000 to 50.000 kHz 5 Hz
Note
* (% of reading + % of full scale)

RTDs and Thermocouples
Measure Accuracy
10 Ω Cu (427): 2 テつ°C
100 Ω Pt (3916) 0.3 テつ°C
100 Ω Pt (3926) 0.3 テつ°C
100 Ω Pt (385) 0.3 テつ°C
200 Ω Pt (385) 0.3 テつ°C
500 Ω Pt (385) 0.3 テつ°C
1000 Ω Pt (385) 0.3 テつ°C
120 Ω Ni (672) 0.3 テつ°C
note For 2-and 3-wire measurement, add 0.4テつ°C
E 0.3 テつ°C
N 0.5 テつ°C
J 0.3 テつ°C
L 0.3 テつ°C
K 0.3 テつ°C
T 0.3 テつ°C
U 0.3 テつ°C
B 0.9 テつ°C
R 1.0 テつ°C
S 0.9 テつ°C
C 0.6 テつ°C
BP 1.2 テつコC
XK 0.4 テつコC
note Accuracy with external cold junction, for internal junction add 0.2 テつ°C
Source Accuracy:
10 Ω Cu (427) 1 テつ°C
100 Ω Pt (3916) 0.1 テつ°C
100 Ω Pt (3926) 0.1 テつ°C
100 Ω Pt (385) 0.1 テつ°C
200 Ω Pt (385) 0.1 テつ°C
500 Ω Pt (385) 0.1 テつ°C
1000 Ω Pt (385) 0.1 テつ°C
120 Ω Ni (672) 0.1 テつ°C
note For 2-and 3-wire simulation, add 0.4 テつ°C
E 0.2 テつ°C
N 0.3 テつ°C
J 0.2 テつ°C
L 0.2 テつ°C
K 0.3 テつ°C
T 0.3 テつ°C
U 0.3 テつ°C
B 0.8 テつ°C
R 0.9 テつ°C
S 0.9 テつ°C
C 0.6 テつ°C
BP 0.5 テつコC
XK 0.4 テつコC
note Accuracy with external cold junction, for internal junction add 0.2 テつ°C

Technical Data
Data Log Functions
Measure functions Voltage, current, resistance, frequency, temperature, pressure
Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length 8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions Voltage, current, resistance, frequency, temperature
Rate 4 steps/second
Trip detect Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage Selectable, 24 V or 28 V
Accuracy 5%
Maximum current 22 mA, short circuit protected
Maximum input voltage 30 V DC
Step Functions
Source Functions Voltage, current, resistance, frequency, temperature
Manual Step Selectable step, change with arrow buttons
Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat

Environmental Specifications
Operating temperature
-10 テつ°C to +50 テつ°C
-20 テつ°C to +50 テつ°C *
Storage temperature
-20 テつ°C to +60 テつ°C
Dust/water resistance
Meets IP52, IEC 529
Operating Altitude
2800 m
Note
* Except frequency and AC

Safety Specifications
Agency Approvals
CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

Mechanical & General Specifications
Size
130 x 236 x 61 mm (5.1テ「竄ャナ x 9.3テ「竄ャツ x 2.4テ「竄ャツ)
Weight
1.4 kg (3 lbs., 1oz.)
Batteries
NiMH 7.2V, 3.5 Ah
Battery life
>10 hours typical
Battery Replacement
Via snap-shut door without opening calibrator; no tools required
Side port connections
Pressure module connector
RS-232 connector for PC interface cable and for HART communication cable
Connection for optional battery eliminator
Data storage capacity
1 week of calibration results
90 day specifications
The standard specification interval for the 744 is 1 and 2 years.
Typical 90 day measurement and source accuracy can be estimated by
dividing the one year "% of reading" or "%of output" specifications by 2.
Floor specifications, expressed as "% of full scale" or
"counts" or "ohms" remain constant.

What's included with the Fluke 744V20

  • FE 744V20 HART Upgrade

Accessories

Click on a category to view a selection of compatible accessories with the FE 744V20 HART Upgrade.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.
$91.27 USD

was $111.99


Learn More


Ask a question about the FE 744V20 HART Upgrade :

Customer Reviews for the Fluke 744V20