Fluke 9011-A-156 Dual Range Dry Block Calibrator

Model: 9011-A-156

This high accuracy calibrator is capable of laboratory as well as field calibrations. It has two independently controlled temperature wells that makes calibrating RTDs and thermocouples faster than ever.

Add In House NIST Traceable Calibration to your 9011-A-156

Clear selected options


$14,402.00 USD

2 to 3 Weeks




 

Fluke 9011-A-156 Dual Range Dry Block Calibrator Offers

Features

  • High accuracy calibrator is capable of laboratory as well as field calibrations
  • Two independently controlled temperature wells make calibrating RTDs and thermocouples faster than ever
  • While readings are being taken at one temperature, the other well can be ramping up or down to the next point
  • Cold block can even be used as a zero-point reference for a thermocouple making measurements in the hot block
  • Allows probes to be calibrated from -30 to 670°C
  • Stabilities to ±0.02°C are possible, and display accuracy is better than ±0.25°C
  • Using multi-hole interchangeable inserts, you can calibrate more probes at the same time (Cold Side has 1 interchangeable well that accommodates a multi-hole insert, plus 4 outer wells, 2 x 1/4", 3/16" & 1/8"; Hot Side has 1 interchangeable well that accommodates a multi-hole insert)
  • With a single RS-232 port for both wells, you can automate your calibration work and be even more efficient
  • Add on MET/TEMP II software and totally automate your calibrations of RTDs, thermocouples, and thermistors
  • Includes a full NIST-traceable calibration report with test data for each well at each point

Applications

Ideal for the following applications: Laboratory, Education, R&D, Calibration Labs, Field Calibration

Fluke 9011-A-156 Specifications

Temperature Range Cold Side: -30 to 140°C (-22 to 284°F)
Hot Side: 50 to 670°C 122 to 1238°F)
Accuracy Cold Side: ±0.25°C (insert wells), ±0.65°C (fixed wells)
Hot Side: ±0.2°C @ 50°C, ±0.4°C @ 400°C,±0.65°C @ 600°C
Stability Cold Side: ±0.02°C @ -30°C, ±0.04°C @ 140°C
Hot Side: ±0.02°C @ 100°C, ±0.06°C @ 600°C
Uniformity Cold Side: ±0.05°C (insert wells), ±0.25°C (fixed wells)
Hot Side: ±0.2°C ±0.05°C
Heating Time Cold Side: 15 mins.; Hot Side: 30 mins.
Cooling Time Cold Side: 30 mins. from 140 to -30°C
Hot Side: 120 mins. from 660 to 100°C
Click here for complete specifications on the Fluke 9011-A-156