Portable three phase power logger designed for energy monitoring and load studies. Large graphical display for instant viewing of results and easy on-screen setup. Ships complete with switchable-range 3000A flexible current transformers and software.

Sorry! This product has been discontinued.


The Fluke 1735 Portable Power Logger Kit With R8100 Borescope has been discontinued, it has been replaced by the Fluke 1736 Energy Logger Kit - Includes R8100 Borescope for FREE



 

Fluke 1735-KIT Offers

Purchase a Fluke 1735 Portable Power Logger and receive a FREE REED R8100 High Definition Borescope.

The Fluke 1735

  • Record power and associated parameters for up to 45 days
  • Monitor maximum power demand over user-defined averaging periods
  • Prove the benefit of efficiency improvements with energy consumption tests
  • Measure harmonic distortion caused by electronic loads
  • Improve reliability by capturing voltage dips and swells from load switching
  • Easily confirm instrument setup with color display of waveforms and trends
  • Measure all three phases and neutral with included 4 flexible current probes
  • View graphs and generate reports with included Power Log software
  • Compact, rugged design with IP65 case, 600 V CAT III and two-year warranty

REED R8100

Features

  • High definition inspection scope detects and diagnoses problems without direct physical or visual access
  • Provides real time imaging only
  • High resolution 2.4" colour TFT LCD monitor with display resolution of 480(W)X 234(H)
  • 17mm imager head with 1m flexible gooseneck retains configured shape and is waterproof
  • Gooseneck is expandable up to 30' with optional cable extensions
  • Four high visibility LED lights provide illumination in dark locations with brightness control
  • 2X zoom button and 180° mirror rotation button
  • Operates on 4 x 1.5V "AA" batteries
Applications

Commonly used in the visual inspection of aircraft engines, aero-derivative industrial gas turbines, steam turbines, diesel engines, and automotive and truck engines. They are also used in manufacturing of machined or cast parts to inspect critical interior surfaces for burrs, surface finish or complete through-holes. Other common uses include forensic applications in law enforcement and building inspection, and in gun-smithing for inspecting the interior bore of a firearm.

Fluke 1735 Specifications

General
Display ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Quality Developed, designed and manufactured according to DIN ISO 9001
Memory 4 MB Flash memory, 3.5 MB for measuring data
Interface RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Sample rate 10.24 kHz
Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supply NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
Operation time with battery Typical > 12 hours without backlight and > 6 hours with backlight high
Dimensions 240 mm x 180 mm x 110 mm
Weight 1.7 kg, including battery
Ambient conditions
Working temperature range -10 °C to +50 °C
Storage temperature range -20 °C to +60 °C
Operating temperature range 0 °C to +40 °C
Reference temperature range 23 °C ± 2 °C
Note The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
Temperature coefficient ± 0.1 % of the measured value per °C from the reference
Intrinsic error Refers to reference temperature, maximum deviation is guaranteed for two years
Operating error Refers to operating temperature range, maximum deviation is guaranteed for two years
Climatic class C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
Housing Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
EMC
Emission IEC/EN 61326-1:1997 class B
Immunity IEC/EN 61326-1:1997
Safety
Safety IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
Protection IP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
V-rms wye measurement
Measuring range 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
Intrinsic error ± (0.2% of measured value + 5 digits)
Operating error ± (0.5% of m. v. + 10 digit)
Resolution 0.1 V
V-rms delta measurement
Measuring range 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
Intrinsic error ± (0.2% of m. v. + 5 digit)
Operating error ± (0.5 % of m. v. + 10 digit)
Resolution 0.1 V
A-rms measurement
Flexi set I ranges 15 A/150 A/3000 A rms (at sine)
Current clamp ranges 1 A/10 A
Resolution 0.01 A
Ranges 150 A/3000 A and 1 A/10 A
Intrinsic error ± (0.5 % of m. v. + 10 digit)
Operating error ± (1 % of m. v. + 10 digit)
Ranges 15 A
Intrinsic error ± (0.5 % of m. v. + 20 digit)
Operating error ± (1 % of m. v. + 20 digit)
The errors of the current probes are not considered.
By using Flexi-Set
Flexi Set measuring error ± (2% of m. v. + 10 digit)
Position influence ± (3 % of m. v. + 10 digit)
CF (typical) 2.83
Note When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting
Measuring range see V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Specified error x (1-[PF])
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error ± (0.7 % of m.v. +15 digit)
Resolution 1 kW
Operating error ± (1.5 % of m.v. + 20 digit)
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
Intrinsic error ± (0.7 % of m.v. +15 digit)
Resolution 1 W to 10 W
Operating error ± (1.5 % of m.v. + 20 digit)
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh)
Intrinsic error ± (0.7 % of m.v.+ F variation error* + 15 digit)
Resolution 1 W to 10 W
Operating error ± (1.5 % of m.v. + F variation error* + 20 digit)
*Frequency variation error
PF (Power factor)
Range 0.000 to 1.000
Resolution 0.001
Accuracy ±1 % of full scale
Frequency measurement
Measuring range 46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error ± (0.2 % of m. v. + 5 digit)
Operating error ± (0.5 % of m. v.+ 10 digit)
Resolution 0.01 Hz
Harmonics
Measuring range To 50th harmonic (< 50 % of nom)
Accuracy
Vm, Im, THDV, THDI IEC 61000-4-7:2002, Class II
Vm > 3% Vn ± 5% Vm
Vm < 3 % Vnom ±0.15% Vnom
Im > 10 % Inom ± 5% Im
Im < 10 % Inom ± 0 5% Inom
THDV for THD < 3% ± 0.15% at Vnom
for THD > 3% ± 5% at Vnom
THDI for THD < 10% ± 0.5% at Inom
for THD > 10% ± 5% at Inom
Vnom Normal voltage range
Inom Nominal current range
Vm and Im are measured values of harmonic m
Events
Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error ± (1% of m.v. + 10 digit)
Operating error ± (2% of m.v. + 10 digit)
Resolution 0.1 V

REED R8100 Specifications

TFT LCD Size 2.4"
Display Resolution 480 x 234
Active Area 48mm x 35.6mm
Viewing Distance 5.9 to 9.8" (15 to 25cm)
Viewing Angle 0 to 180°
Sensor Size 1/4" CMOS
Sensor Pixels 300,000
Max. Resolution 640 x 480
Max. Frames 30 fps
Depth of Field (DOF) 10mm to infinity
Camera Diameter 0.66" (17mm); Length: 39" (1m)
Power Supply 4 x 1.5V AA batteries