True-rms Basic Multimeter designed for basic electrical testsThe Fluke 113 Basic Multimeter gives utility users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems.
The Fluke 113 Basic Multimeter has significant improvements over Fluke’s original 7-600, and other utility multimeters. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity.
The Fluke 113 Basic Multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this new meter is a must have for the utility users toolbox.
What's Included:
- Fluke TL75 test leads
- Holster
- Users manual
- and 9 V battery (installed).
| Specifications |
| VCHECK 1,2 |
| Range |
6.000 V |
|
60.00 V |
|
600.0 V |
| Resolution |
0.001 V |
|
0.01 V |
|
0.1 V |
| Accuracy |
DC, 45 to 500 Hz:2.0 % + 3 |
|
500 Hz to 1 kHz: 4.0 % + 3 |
|
| Diode test 3 |
| Range |
2.000 V |
| Resolution |
0.001 V |
| Accuracy |
2.0 % + 3 |
|
| Continuity3 |
| Range |
|
| Resolution |
|
| Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects
opens or shorts of 500 μs or longer |
|
| Ω3 |
| Range |
600.0 Ω |
|
6.000 kΩ |
|
60.00 kΩ |
| Resolution |
0.1 Ω |
|
0.001 kΩ |
|
0.01 kΩ |
| Accuracy |
0.9 % + 2 |
|
0.9 % + 1 |
|
0.9 % + 1 |
|
| Capacitance3 |
| Range |
1000 nF |
|
10.00 μF |
|
100.0 μF |
|
9999 μF |
| Resolution |
1 nF |
|
0.01 μF |
|
0.1 μF |
|
1 μF |
| Accuracy |
1.9 % + 2 |
|
1.9 % + 2 |
|
1.9 % + 2 |
|
100 μF - 1000 μF: 1.9 % + 2 |
|
> 1000 μF: 5 % + 20 |
|
Notes:
1 All VChek voltage ranges are specified from 60 counts to
100 % of range. Because inputs below 60 counts are not specified, it is
possible and normal for this and other true-rms meters to display
non-zero readings when the test leads are disconnected from a circuit
or are shorted together.
2 Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3 After measuring voltage, a wait time of 1 minute is
required to maintain accuracy of ohms, capacitance, diode test, and
continuity.
| Specifications |
| Maximum voltage between any terminal and earth ground | |
| Display |
|
3 3/4-digits, 6000 counts, updates 4/sec |
|
| Operating temperature |
|
-10 °C to 50 °C (14 °F to 122 °F) |
|
| Storage temperature |
|
-40 °C to 60 °C (-22 °F to 140 °F) |
|
| Temperature coefficient |
|
0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C) |
|
| Operating altitude | |
| Storage altitude | |
| Relative humidity |
|
95 % to 30 °C |
|
75 % to 40 °C |
|
45 % to 50 °C |
|
| Battery type |
|
9 Volt Alkaline, ANSI 1604A / IEC 6F22 |
|
| Battery life |
|
Alkaline: 300 hours typical, without backlight |
|
| Shock |
|
1 Meter drop per IEC 61010-1-2001 |
|
| Vibration |
|
Per MIL-PRF-28800 for Class 2 instrument |
|
| Size (HxWxL) |
|
167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in) |
|
| Weight | |
| Safety |
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No
61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for
measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 |
|
| EMI regulations |
|
Complies with FCC Part 15, Class B |
|
| Specifications |
| VCHECK |
| Input Impedance (Nominal) |
~3 kΩ < 300 pF |
|
| VCHECK |
| Common Mode Rejection Ratio (1 kΩ Unbalanced) |
> 60 dB at dc, 50 or 60 Hz |
|
| Ω |
| Open Circuit Test Voltage |
< 2.7 V dc |
| Full Scale Voltage |
< 0.7 V dc |
|
| Diode test |
| Open Circuit Test Voltage |
< 2.7 V dc |
| Full Scale Voltage |
2.000 V dc |
|
| Ω |
| Short Circuit Current |
< 350 μA |
|
| Diode test |
| Short Circuit Current |
< 1.0 mA | |
No user reviews available.