Home » Other Tools » Indoor Air Quality (IAQ) » Fluke i50S AC Scope Current Probe
Fluke i50S AC Scope Current Probe
Part Number:
FE I50S
In Stock?
Stock may be available
please call (877)766-5412 to confirm
please call (877)766-5412 to confirm
Quantity
Price:
$2162.95
USD (change)




Designed for use with bench oscilloscopes, the Fluke i50s Current Probe offers an ergonomic, robust and high performing solution for the measurement of DC and AC currents up to 50 MHz.
With a permanent nominal current of 30 A RMS and a measuring capacity of 50 A for 10 s, as well as exceptional immunity to high common mode voltages (dv/dt = 5 kV/_s,) amplitude = 1,5 kV, error < 0,05 % of IPN), the Fluke i50s considerably widens the possibilities of accurate measurement of commutation currents.
What's Included:
With a permanent nominal current of 30 A RMS and a measuring capacity of 50 A for 10 s, as well as exceptional immunity to high common mode voltages (dv/dt = 5 kV/_s,) amplitude = 1,5 kV, error < 0,05 % of IPN), the Fluke i50s considerably widens the possibilities of accurate measurement of commutation currents.
What's Included:
- Carrying case
- Power supply cable
- Calibration certificate
- Power supply adapter
- Earthing lead
- Operators manual
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- Bandwidth DC up to 50 MHz
- Nominal current 30 A
- Max. current 50 A, < 10 s
- Automatic zero adjustment and degauss functions
- Overheating and Head Unlocked warning
- Rise time < 7 ns
- External magnetic field rejection rate AC and DC 60 dB
- Rejection rate of fast dv/dt (5kV/_s) < 15 mA t
| Electrical Characteristics | |||||||
| Nominal current (In) |
| ||||||
| Measuring range (duration <10 sec) |
| ||||||
| Output Sensitivity |
| ||||||
| Overall accuracy (dc to 100 Hz at 25 °C) |
| ||||||
| Gain variation (max) |
| ||||||
| Step response |
| ||||||
| Frequency response |
| ||||||
| Insertion impedance (ZI) |
| ||||||
| External magnetic field rejection rate |
| ||||||
| Rejection rate of fast dV/dt at 5 kV/ μs |
| ||||||
| Output noise level (measured with a filter at 25 MHz) |
| ||||||
| Output noise level (measured with a filter at 25 MHz) |
| ||||||
| Dynamic Characteristics | |||
| Bandwidth |
| ||
| Frequency derating (see Figure 4) |
| ||
| Rise time, (10 % to 90 %) |
| ||
| Delay time |
| ||
| Overshoot |
| ||
| General Characteristics | |||||
| Aperture dimensions |
| ||||
| Max primary conductor temp |
| ||||
| Dielectric withstand |
| ||||
| Working Voltage |
| ||||
| Operating temperature |
| ||||
| Storage temperature |
| ||||
| Maximum Altitude |
| ||||
| Maximum relative humidity |
| ||||
| Environment |
| ||||
| Power supply |
| ||||
| Current consumption at nominal |
| ||||
| Current consumption during demagnetization |
| ||||
| Output cable length |
| ||||
No user reviews available.