Fluke i30s AC/DC Current Clamp

Part Number:
FE I30S
In Stock?
Yes! Available up to 1 units

Quantity

Price:
$504.49 USD (change)

 

The Fluke i30s current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.
   
The Good:


The Bad:


The Bottom Line:

Full Review

Electrical specifications
Current range

20 A ac rms or dc
Measuring range

± 30 A
Output sensitivity

100 mV/A
Accuracy (at +25 °C)

± 1 % of reading ± 2 mA
Resolution

± 1 mA
Load impedance

> 100 kΩ
Conductor position sensitivity

± 1 % relative to center reading
Frequency range

DC to 100 kHz (- 0.5 dB)
Phase shift below 1 kHz

< 2 degrees
Temperature coefficient

± 0.01 % of reading/°C
Power supply

9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)

300 V ac rms or dc

General specifications
Maximum conductor size

19 mm diameter
Output connection

Safety BNC connector, supplied with safety 4 mm adapter
Output zero

Manual adjust via thumbwheel
Cable length

2 meters
Operating temperature range

0 °C to +50 °C
Storage temperature range (with battery removed)

-20 °C to +85 °C
Operating humidity

15 % to 85 % (non-condensing)
Weight

250 g
Safety standards

BS EN 61010-1: 2001

BS EN 61010-2-032: 2002

BS EN 61010-031: 2002

300 Vrms, Category III, Pollution Degree 2

Use of the probe on uninsulated conductors is limited to 300 V acrms or dc and frequencies below 1 kHz.
EMC Standards

EN 61326: 1998 +A1, A2, & A3

No user reviews available.

Have a Question?

Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

Name
Email
Message
 
booleanboolean