Fluke 87V/AEK Advanced Electronic Kit

Sorry, this product is discontinued and is no longer available for purchase. Please call 1-877-766-5412 to find a suitable replacement.Fluke 87V/IMSK Digital Multimeter with Fluke i400 Current Clamp Combo Kit is a suggested replacement model.

The Fluke 87V offers accuracy and diagnostics for maximum industrial productivity in the tool box or on the bench.

The Fluke 87V multimeter has improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electromechanical equipment.

With its newly incorporated selectable low pass filter, the Fluke 87V allows troubleshooters to take accurate voltage, current and frequency measurements on the output side of the drive at either the drive itself or the motor terminals.

The Fluke 87V/AEK Advanced Electronic Kit has combined the best selling feature packed 87V Multimeter with the TL81A test lead set for the complete solution to electronic circuit board troubleshooting. Together they provide the ability to probe and troubleshoot even the most densely populated circuit boards more efficiently by providing all the needed accessories a professional electronic engineer would require.

Features for maximum productivity

  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
  •  Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
  •  Large digit display with bright, two-level backlight

Electrical safety
All inputs are protected to Category III, 1000 V and Category IV 600 V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.


What's Included:

  • Fluke 87V Multimeter with temperature, frequency, capacitance, 250 μs peak, and min-max
  • Fluke TL81A Deluxe Electronic Test Lead Set - 22 of the most useful accessories for making measurements in low energy, electronic applications
  • New! Fluke C115 Deluxe carrying case with shoulder strap
The Good:


The Bad:


The Bottom Line:

Full Review

  • True-rms ac voltage and current for accurate measurements on non linear signals
  • Selectable filter for accurate voltage and frequency measurements on motor drives
  • 0.05 % dc accuracy
  • 4-1/2 digit mode for precise measurements
  • Built-in thermometer lets you carry one less tool
  • Large display digits and two-level bright white backlight for increased visibility
  • 10,000 µF capacitance range for components and motor caps
  • Peak capture to record transients as fast as 250 µs
  • Measure up to 1000 V ac and dc
  • Measure up to 10 A, 20 A for up to 30 seconds
  • Auto and manual ranging for maximum flexibility
  • Analog bargraph
  • Resistance, continuity and diode test
  • Frequency to 200 kHz and % duty cycle
  • Min/Max and average recording to capture variations automatically
  • Relative mode to remove test lead resistance from low ohms measurements
  • Improved sleep mode for long battery life
  • Access door for fast battery changes without breaking the calibration seal
  • Limited lifetime warranty
  • Removable holster with built in test lead and probe storage
  • Cat IV 600 V and Cat III 1000 V electrical safety ratings
  • Basic test leads and alligator clips
  • Bead type thermocouple temperature probe

Correctly measure pulse-width modulated motor drive signals

Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.

  • Unique function for accurate measurements of noisy pulse-width modulated AC voltage.
  • Measures correctly at the ASD and at the motor terminals
  • Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
  • Measure AC current with an optional current clamp accessory
  • Compare reading from the 87V with the display on the ASD
  • Special shielding blocks high frequency, high-energy noise generated by large drive systems
Complex PWM drive signals are not a problem for the Fluke 87V
Pulse-width modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 micro-second pulses can cause erratic behavior in some test equipment.
Specifications
Voltage DC
Maximum Voltage:1000V
Accuracy: ±(0.05%+1)
Maximum Resolution:10 µV
Voltage AC
Maximum Voltage:1000V
Accuracy:±(0.7%+2) True RMS
AC Bandwidth20kHz*

*with low pass filter; 3db @ 1kHz
Maximum Resolution:0.1 mV
Current DC
Maximum Amps:10A (20 A for 30 seconds maximum)
Amps Accuracy:±(0.2%+2)
Maximum Resolution:0.01 µA
Current AC
Maximum Amps:10A (20 A for 30 seconds maximum)
Amps Accuracy:±(1.0%+2) True RMS
Maximum Resolution:0.1 µA
Resistance
Maximum Resistance:50 MΩ
Accuracy:±(0.2%+1)
Maximum Resolution:0.1Ω
Capacitance
Maximum Capacitance9,999 µF
Accuracy±(1%+2)
Maximum Resolution0.01 nF
Frequency
Maximum Frequency200 kHz
Accuracy±(0.005%+1)
Maximum Resolution0.01 Hz
Duty Cycle
Maximum Duty Cycle99.9%
Accuracy±(0.2% per khz +0.1%)
Maximum Resolution0.1%
Temperature Measurement
-200.0°C - 1090°C
-328.0°F - 1994.0°F
excluding probe
80 BK Temperature Probe

-40.0°C - 260°C

-40.0°F - 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum Conductance60.00 nS
Accuracy±(1.0%+10)
Maximum Resolution0.01 nS
Diode

Range 3 V
Resolution:1 mV
Accuracy:± (2 % + 1)
Duty Cycle Range
Accuracy:Within ± (0.2% per kHz + 0.1 %)

Environmental Specifications
Operating Temperature

-20°C to +55°C
Storage Temperature

-40°C to +60°C
Humidity (Without Condensation)

0% - 90% (0°C - 35°C)

0% - 70% (35°C - 55°C)
Operating Altitude

2000 m

Safety Specifications
Overvoltage category

EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals

UL, CSA, TÜV, VDE listed

Mechanical & General Specifications
Size

201 x 98 x 52 mm (with holster)
Weight

355 g
Weigh With Holster and Flex-Stand

624 g
Display
Digital:6000 counts updates 4/sec.

(Model 87 also has 19,999 counts in high-resolution mode.)
Analog:32 segments, updates 40/sec.
Frequency:19,999 counts, updates 3/sec at > 10 Hz.
Warranty

Lifetime
Battery Life
Alkaline:~400 hours typical, without backlight
Shock

1 Meter drop per IEC 61010-1:2001
Vibration

Per MIL-PRF-28800 for a Class 2 instrument
No user reviews available.
Recommended Accessories
The Fluke 87V/AEK Advanced Electronic Kit has 1 recommended accessory.        Click to show all accessories


Test Leads
Name Price Quantity
Fluke TLK291 fused test probe set $65.95

Have a Question?

Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

Name
Email
Phone
Message
In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.

Enter Passcode: