A complete automotive diagnostic package with everything you need in an automotive multimeter
The new Fluke 88V has improved measurement functions, troubleshooting features and accuracy to solve more problems on conventional and hybrid vehicles. The 88V is made in the U.S.A. and carries the industry leading lifetime warranty.
The Fluke 88V operates very similar to the classic Fluke 88, but with more problem solving power, safety, convenience and impact protection.
Combo Kit Includes: 88V multimeter, TL224 silicone test leads, AC285 long reach alligator clips, TP220 test probes, RPM 80 inductive RPM pick-up, magnet and strap, 80BK temperature probe, two automotive backprobe pins, insulation piercing probe, C800 durable carrying case, holster, 9V battery (installed), Getting Started Manual, and CD with detailed manual.
The new 88V is independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
| DCV |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 88 V: ±(0.1%+1) |
| Best Resolution: |
Fluke 88 V: 0.01 mV
| |
| ACV |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 88 V: ±(0.5%+2) |
| AC Bandwidth: |
Fluke 88 V: 5kHz |
| Best Resolution: |
0.01 mV | |
| AC Current |
| Maximum Amps: |
10A |
| Amps Accuracy: |
Fluke 88 V: ±(1.2%+2) |
| Best Resolution: |
0.001 mA | |
| DC Current |
| Maximum Amps: |
10A |
| Amps Accuracy: |
Fluke 88 V: ±(0.4%+2) |
| Best Resolution: |
Fluke 88 V: 0.001 mA | |
| Resistance |
| Maximum Resistance: |
50 MΩ |
| Accuracy: |
Fluke 88 V: ±(0.4%+1) |
| Best Resolution: |
0.1Ω | |
| Capacitance |
| Maximum Capacitance: |
9,999 µF |
| Accuracy: |
±(1%+2) |
| Best Resolution: |
0.01 nF | |
| Frequency |
| Maximum Frequency: |
200 KHz |
| Accuracy: |
±(0.005%+1) |
| Best Resolution: |
0.01 Hz | |
| Duty Cycle |
| Maximum Duty Cycle: |
99.9 % |
| Accuracy: |
within 2% per KHz +0.1% |
| Best Resolution: |
0.1 % | |
| Temperature Measurement |
|
-200.0°C - 1090°C |
|
-328.0°F - 1994.0°F, 1.0% excluding probe | |
| 80 BK Temperature Probe |
|
-40 °C - 260 °C |
|
-40 °F - 500 °F, 2.2 °C or 2% whichever is greater | |
| Conductance |
| Maximum Conductance: |
60.00 nS |
| Accuracy: |
±(1.0%+10) |
| Maximum Resolution: |
0.01 nS | |
| Operating Range |
| Operating Temperature: |
-20 °C - 55 °C |
| Storage Temperature: |
-40 °C - 60 °C | |
| Physical |
|
5.2 cm x 9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”) |
|
624 g (22 oz.) | |
Product brochures
Virtual demos
No user reviews available.