Fluke 1623 Basic GEO Earth Ground Tester Kit

Model: 1623-KIT

Includes the Fluke 1623 earth ground resistance tester for 3- and 4-point testing plus short-range ground resistance test kit with cables and ground stakes.

Sorry! This product has been discontinued.


The Fluke 1623 Basic GEO Earth Ground Tester Kit has been discontinued, it has been replaced by the Fluke 1623-2-KIT Basic Geo Earth Ground Tester Kit



 

Fluke 1623 Offers

  • Adjustable stroke length can be set to limit the pressure per stroke
  • 1/4 in NPT male to 1/4 in BSP female
  • 1 meter of hose
  • (2) 1/8 in NPT male quick connects
  • 1/8 NPT female to 1/4 in BSP female
  • Seal Kit
  • Instruction sheet

Specifications:

RA 3-pole ground resistance measurement (IEC 1557-5)

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(2% of reading + 3 digit)
  • Operating Error: ±(5% of reading +3 digit)

RA 4-pole ground resistance measurement (IEC 1557-5)

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(2% of reading + 3 digit)
  • Operating Error: ±(5% of reading +3 digit)

RA 3-pole ground resistance measurement with current clamp

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(7% of reading + 3 digit)
  • Operating Error: ±(10% of reading +3 digit)

RA 4-pole selective ground resistance measurement with current clamp

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(7% of reading + 3 digit)
  • Operating Error: ±(10% of reading +3 digit)

Stakeless ground loop measurement

  • Measuring Voltage: Vm = 48Vac
  • Measure Frequency: 128Hz (125 Hz on request)
  • Noise Current (lext): Max. let = 10A(ac) (RA <20Ω)
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(7% of reading + 3 digit)
  • Operating Error: ±(10% of reading +3 digit)

General Specifications

  • Display: 1999 digit LCD – display with special symbols, digit height 25 mm, fluorescent backlight
  • Dimensions length: 8.7 in (220 mm), width 4.8 in (122 mm), depth 3.5 in (89 mm)
  • Weight: 1.03 lb (467 g)
  • Material Wetted materials: aluminum, silicon, neoprene, stainless steel, Buna-N

KIT INCLUDES:

  • Fluke 1623 Tester
  • 2 test leads
  • 4 earth ground stakes
  • 3 cable reels with wire (2-25 m, 1-50 m)
  • 2 clamps (one inducing, one sensing)
  • Batteries
  • Users manual
  • Rugged carrying case

Accessories

Click on a category to view a selection of compatible accessories with the Fluke 1623 Basic GEO Earth Ground Tester Kit.


Ask a question about the Fluke 1623 Basic GEO Earth Ground Tester Kit:

comments powered by Disqus

Review the Fluke 1623 Basic GEO Earth Ground Tester Kit

" data-description="Includes the Fluke 1623 earth ground resistance tester for 3- and 4-point testing plus short-range ground resistance test kit with cables and ground stakes.">