Fluke Ti55FT-20 IR FlexCam Thermal Imager with IR-Fusion

Part Number:
FE Ti55FT-20
In Stock?
Please call for availability.

Quantity

Price:
$26490.00 USD (change)

 

Choose the Fluke Ti50 or the Fluke Ti55 models when you need the best images. They feature 320 x 240 detectors with industry leading thermal sensitivity (≤ 0.05 °C NETD) for high resolution, ultra high-quality images. In addition, with a 60 Hz detector acquisition rate temperatures are displayed live on the large 5-inch color display.

The FT models feature the innovative IR-Fusion™ technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page.

See exactly what you are viewing
Fluke IR-Fusion™ technology (available on FT models) links a real world visual image with a thermal image. It merges the two images into one, with the possibility to blend between the two images or create picture-in-picture combinations. Alarm limits can be superimposed over the visible light image to exactly pinpoint the components exceeding a specified temperature limit. Both the visual images and thermal images are available for use in reports. This speeds up documentation by reducing the need to look for individual images taken with a separate digital camera. IR Fusion helps to better identify and report suspect components and enable the repair to be done right the first time.

Large, sharp thermal images
Thanks to the largest display (five-inch) available on this type of thermal imager in combination with low-noise VOx sensors, the Fluke IR FlexCam units produce exceptionally high-quality images making even the smallest temperature differences visible. This is comparable with images normally only obtained on far more expensive instruments.

A sharp image in every situation
The innovative 180 ° articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring.

Make anomalies visible
Thanks to built-in functions like AutoCapture, the IR FlexCam Thermal Imagers help to troubleshoot difficult problems. The instrument is easily set up to automatically capture only those images where a temperature limit is exceeded. This way, difficult to find intermittent problems can be captured and analyzed quicker by concentrating only on the images containing the anomalies.

Analysis and reporting comes standard
The SmartView™ software (supplied with the unit) includes a complete range of infrared image viewing, analysis, annotation and reporting tools. It even allows for customized reports to accommodate specific company work processes or requirements like multiple image reporting and comparisons. To find out more select SmartView on the side navigation of this page.

Radiometric measurement – the ‘data behind the picture’
Fully radiometric thermal imagers capture and store calibrated temperature data for the matrix of thousands of points that make up a thermal image. This makes it possible to perform detailed analysis and change key parameters like emissivity or temperature range either in the field on the camera or in the office using the PC software.

Typical applications:
  • Predictive maintenance – Identify electrical and mechanical problems before they cause failure
  • Power/utilities – Real-time analysis of substations, transmission lines and equipment
  • Process monitoring – Real-time observation to ensure efficient and safe operation
  • Research and development – Quantify heat patterns to improve product designs
  • Electronic design – Close up circuit board analysis
The Good:


The Bad:


The Bottom Line:

Full Review

  • AC Operation Yes
  • Accuracy 2% Accuracy
  • Articulating Lens Yes
  • Auto Blending Yes
  • Auto Power Off Yes
  • Color Alarm Yes
  • Custom Boxes/Pointers Yes
  • Custom Field/Text Annotations Yes
  • Detector Size 320 x 240 Sensor
  • Detector Type Uncooled Microbolometer, Focal Plane Array
  • Display 5.0” LCD Display
  • Emissivity Correction Yes
  • Flash and Torch Light Yes
  • Focus Manual, 1-handed SmartFocus
  • Fully Radiometric Images Yes
  • Hot/Cold Point Detection Yes
  • Image Frequency 60Hz Frequency
  • IR Digital Zoom 2x, 4x, 8x
  • IR Digital Zoom 2x, 4x, 8x IR Digital Zoom
  • IR/Visual Fusion Image Yes
  • Laser Pointer Yes
  • Measurement Mode Center Box (area, min/max, avg)
  • Measurement Mode Center Point
  • Measurement Mode User Defined Spots/Boxes
  • Memory Type 1GB Flash Memory
  • Number of Temperature Ranges 3 Temperature Ranges
  • On-Board Analysis Yes
  • On-Screen Analysis Yes
  • Optional Lens Telephoto
  • Optional Lens Wide Angle
  • Optional Lenses Yes
  • Palettes 8
  • Palettes 8 Color Palettes
  • Picture in Picture Yes
  • Programmable AutoCapture Yes
  • Reflected Correction Yes
  • Reflected Temperature Correction Yes
  • Sleep mode Yes
  • Software Yes
  • Temperature Range °C -20°C to 600°C Range
  • Temperature Range °F -4°F to 1112°F Range
  • Thermal Image Yes
  • Thermal Sensitivity (NETD) 0.05°C Sensitivity
  • Video Output Yes
  • Visible Color Alarms Yes
  • Visual Light Image Yes
  • Windows CE-Based Navigation Yes
Accuracy±2°C or 2% whichever is greater
Battery operating time2 hours continuous
Battery re-charge time3 Hours
Detector Size320 x 240
Dimensions162 x 262 x 101 mm (6.5 in x 10.5 in x 4.0 in)
Display5 High Resolution LCD
Field of View (FOV)23°horizontal x 17°vertical
Image Frequency60/7.5
Imager File FormatsIS2
IP RatingIP54
Maximum Images> 1000 images
Memory TypeCompact Flash Card (1 GB)
Minimum Focus Distance15 cm (approx. 6 in)
Number of Temperature Ranges3
Operating Temperature-10 to +50°C (14°F to 122°F)
Relative Humidity10% to 95% non-condensing
Software File FormatsBMP, JPG, GIF, PNG, TIF, DIB, JPE, JFIF, JPEG, TIFF
Spatial Resolution (IFOV)1.30
Spectral Band8µm to 14µm
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Temperature Range °C-20°C to 600°C
Temperature Range °F-4°F to 1112°F
Thermal Sensitivity (NETD)≤0.05°C at 30°C (50 mK)
Video OutputRS170 EIA/NTSC or CCIR/PAL composite video
Warranty2 years
Weight1.95 kg (4.3 lb)
Fluke SmartView IR analysis and reporting software
        
Fluke SmartView™ IR analysis and reporting softwareFluke SmartView™ software is included with each Fluke IR FlexCam® Thermal Imager. This powerful software is a modular suite of tools that annotates, views, edits and analyzes IR images. It also generates fully customizable and professional-looking reports in a few easy steps. The software is easy to use for maintenance personnel, yet delivers the performance specialized thermographers require for advanced analysis.



Image viewing and editing

  • Displays an array of open images for convenient selection and analysis
  • A simple mouse click displays the temperature at any given point
  • Color palettes, reference images, markers and emissivity can be edited
Extensive annotation possibilities
  • Add annotations to images in the camera or in the PC software
  • Input information such as locations, category and other notes
  • Reference images can be linked together for good/bad and before/after analysis
  • Annotations can be included in reports
Detailed analysis and total image control
  • Alter emissivity and background temperature to enhance contrast or display detail more effectively
  • A complete set of marker tools are provided (Hot, Cold, Center Point, Center Box, etc.)
  • Five viewing modes enable image optimization based on application needs (IR-Fusion models only)       
Simplified report generation
  • Generate professional customized reports fast
  • One-click report generation for a quick result
  • Choice of features including before/after, IR plus visible light, annotations, supporting data and graphics
  • Report wizard guides the user through report generation








Navigate, analyze and enhance IR images     Organize data with extensive annotations     Optimize images and quickly reveal issues


System requirements

  • Windows® 98SE/ME/NT4/2000/XP
  • A web browser for product registration. Internet Explorer 5.0 or newer or Netscape® 5.0 or newer
  • CompactFlash memory card reader
  • 20 MB available disk space, not counting space requirements for web browser
  • 16-bit color, 800 x 600 resolution video or better’
  • Color printer for printing the images
  • CD-ROM drive (for installing SmartView software)

Product brochures

Building Diagnostics

Electrical distribution

Electro-mechanical

Electronics

In plant electrical

Mechanical systems

Other

Process monitoring

Product training

Technical training

Product manuals

Virtual demos

No user reviews available.

Have a Question?

Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

Name
Email
Message