Fluke 62 MAX+/323/1AC IR Thermometer Clamp Meter and Voltage Detector Kit

Model: 62-MAX+/323/1AC | Order No: 62MAX+/323/1AC

Designed to help electricians and HVAC technicians solve problems faster. Featuring the Fluke 323 True-RMS Clamp Meter, Fluke 62 MAX+ IR Thermometer, and Fluke 1AC II VoltAlert Voltage Detector.

Add In House NIST Traceable Calibration to your 62 MAX+

Add In House NIST Traceable Calibration to your 1AC II

Add In House NIST Traceable Calibration to your 323

Clear selected options


$269.99 USD

was $299.99

1 to 2 Weeks




 

Fluke 62 MAX+ Features

  • Dust and water-resistant: IP54 rated for dust and water resistance.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box.
  • Distance to spot: Precise laser technology makes for more accurate and repeatable measurements.
  • Dual Lasers:The 62 MAX+ has dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots.
  • Large, backlit display: Large screen makes data easier to read, even in dark areas.
  • Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.
  • Alarm: Hi and Lo alarms for rapid display of measurements outside the limits.
  • Power: Both the 62 MAX and 62 MAX+ are powered by a single, standard AA battery.

Fluke 323 Features

  • Slim, ergonomic design
  • CAT IV 300V/CAT III 600 V safety rating
  • Hold button
  • Two-year warranty
  • Soft carrying case

Fluke 1 AC II VoltAlert Features

  • Voltbeat™ technology and continuous self-test - so you always know it's working
  • Upon detection, tip glows and beeper sounds
  • CAT IV 1000 V for added protection
  • Expanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model
  • 20 V to 90 V AC control circuit model also available
  • Two-year warranty

Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit

This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use the clamp meter and voltage detector to find out more about the problem

What's Included in the Kit:

  • Fluke 62 MAX+ IR Thermometer
  • Fluke 323 True-rms Clamp Meter
  • Fluke 1AC II VoltAlert Voltage Detector
  • C115 Soft Case

About the Fluke 62 MAX+

Small in size extremely accurate and very easy to use. IP54 rated for dust and water resistance.

Designed with your on-the-job needs in mind, the new Fluke 62 MAX and 62 MAX + infrared thermometers are everything you'd expect from the experts in measurement tools. Small in size, extremely accurate and very easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and 62 MAX + are so tough, they're the only IR thermometers around you can handle without care.
If you've ever used an infrared thermometer, then you may have been fooled regarding the temperature reading. That's because IR thermometers project a measurement cone at a surface and take the average temperature of the cone at the target. Although most IR thermometers have a laser pointer, a laser is a line, not a cone, and you may think that you're getting temperature at the laser point only. Fluke's 62 Max+ uses two rotating laser pointers that show you the size of the measurement area. It covers the temperature range from -30°C to 650°C with a response time less than 300 ms. The Model 62 Max uses a single laser pointer and covers the temperature range from -30°C to 500°C.
The Max 62 and Max 62+ are designed to withstand drops up to 3 m. Is screen is located in a position and with a viewing angle (15°) that, in many cases, lets you see the display without having to move the thermometer from the measuring point. For most measurements, you simply pull the trigger once you've identified the measurement point.

Why IR Thermometers?

Temperature is often the first indication of potential problems in electrical and mechanical applications. But how can you easily determine if an electrical panel has a hot spot, a motor is overheating or an HVAC system is inefficient? The answer is with an infrared (IR) thermometer. With handheld, non-contact IR thermometers, you can instantly measure equipment temperatures in hard-to-reach or hazardous areas. And with early detection of abnormal temperatures comes early correction of problems.

Why Fluke 62 MAX and Fluke 62 MAX+?

Designed with your on-the-job needs in mind, the new Fluke 62 MAX and 62 MAX+ infrared thermometers are everything you'd expect from the experts in measurement tools: small in size, extremely accurate and very easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and 62 MAX+ are so tough, they're the only IR thermometers around you can handle without care.


About the Fluke 323 Clamp Meter

True-rms measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.

Measurement capability
  • 400 A ac current measurement
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 4 kΩ with continuity detection

About the Fluke 1 AC II VoltAlert Voltage Detector

The next generation VoltAlert™ AC non-contact voltage testers from Fluke are easy to use - just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there's voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test for energized circuits in the workplace or at home.

Fluke 62 MAX+ Specifications

Specifications

Temperature Range

Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62+ MAX -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX ±1.5 °C or ±1.5% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Fluke 62+ MAX ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX <500 ms (95% of reading)
Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

Fluke 62 MAX 10:1 (calculated at 90% energy)
Fluke 62+ MAX 12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62+ MAX ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
Fluke 62 MAX 10 hours with laser and backlight on
Fluke 62+ MAX 8 hours with laser and backlight on

Physical Specifications

Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II

Fluke 323 Clamp Meter Specifications

Specifications
323324325
AC currentRange400.0 A40.00 A/400.0 A40.00 A/400.0 A
Accuracy2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
1.5 % ± 5 digits
(45 Hz to 400 Hz)
Note: Add 2 % for
position sensitivity
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
DC currentRange--40.00 A/400.0 A
Accuracy--2 % ± 5 digits
AC voltageRange600.0 V600.0 V600.0 V
Accuracy1.5 % ± 5 digits1.5 % ± 5 digits1.5 % ± 5 digits
DC voltageRange600.0 V600.0 V600.0 V
Accuracy1.0 % ± 5 digits1.0 % ± 5 digits1.0 % ± 5 digits
ResistanceRange400.0 Ω/ 4000 Ω400.0 Ω/ 4000 Ω400.0 Ω/ 4000 Ω/ 40.00 kΩ
Accuracy1.0 % ± 5 digits1.0 % ± 5 digits1.0 % ± 5 digits
Continuity≤ 70 Ω≤ 30 Ω≤ 30 Ω
Capacitance-100.0 μF to 1000 μF100.0 μF to 1000 μF
Frequency--5.0 Hz to 500.0 Hz
AC responseTrue-rmsTrue-rmsTrue-rms
Backlight-YesYes
Data holdYesYesYes
Contact temperature--10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
-10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
Min/Max--Yes
SizeH x W x D (mm)207 x 75 x 34207 x 75 x 34207 x 75 x 34
Max wire diameter30 mm (600 MCM)30 mm (600 MCM)30 mm (600 MCM)
Weight265 g208 g283 g
Category ratingCAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
WarrantyTwo-yearTwo-yearTwo-year

Fluke 1 AC II VoltAlert Specifications

Operating principle

Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.
Voltage sensing ranges

Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model
Detector tip style

Blade or round, depending on model
Light source

One high intensity red LED
Agency Approvals

c CSA us, CE, TUV, C-Tick
Safety Rating

1000 V, CAT IV
IP Rating

IP 40
Operating Temperature

-10 °C to 50 °C
Operating humidity ranges
0 % to 95 %(0 °C to 30 °C)
0 % to 75 %(30 °C to 40 °C)
0 % to 45 %(40 °C to 55 °C)
Operating Altitude

3000 meters
Batteries

2 AAA alkaline batteries included
Click here for complete specifications on the Fluke 62-MAX+/323/1AC

Ask a question about the Fluke 62 MAX+/323/1AC IR Thermometer Clamp Meter and Voltage Detector Kit:

comments powered by Disqus

Review the Fluke 62 MAX+/323/1AC IR Thermometer Clamp Meter and Voltage Detector Kit

" data-description="Designed to help electricians and HVAC technicians solve problems faster. Featuring the Fluke 323 True-RMS Clamp Meter, Fluke 62 MAX+ IR Thermometer, and Fluke 1AC II VoltAlert Voltage Detector.">