Fluke 43B Power Quality Analyzer

Model: 43B/003

Popular single phase power quality analyzer designed for simple short-term testing and troubleshooting on electrical devices or panels. Ships complete with a 400A clamp-on current probe.

Add In House NIST Traceable Calibration to your 43B/003

Clear selected options


Complete Kit

$3,499.99 USD





 

Maintain power systems, troubleshoot power problems, diagnose equipment failures

The Fluke 43 Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures. All in a rugged handheld package.

  • Combines the most useful capabilities of a power quality analyzer, multimeter and scope
  • New! Calculates 3-phase power on balanced loads, from a single-phase measurement
  • Measures power harmonics, and captures voltage sags, transients and inrush current
  • Monitoring functions help track intermittent problems and power system performance
  • Menus use familiar electrical terminology
  • New! Toggle through the most commonly used power quality modes with a single keystroke
  • Records two selectable parameters for up to 16 days
  • New! 20 measurement memories to save/recall screens and data with cursor readings
  • New! FlukeView® Software can log harmonics and all other readings over time
  • New! FlukeView Software provides a complete harmonics profile up to the 51st harmonic
  • Measures resistance, diode voltage drop, continuity, and capacitance
  • Users / applications manual and power quality video to help answer tough questions
  • Complete package with voltage probes and 500A current clamp, FlukeView Software and optically isolated interface cable
  • 3 year warranty on the Fluke 43B, 1 year on accessories
On screen graphics show you how to set up 3-phase power measurements

On screen graphics show you how to set up 3-phase power measurements.

Watts, power factor, displacement power factor
  • Watts, power factor, displacement power factor (Cos ), VA and VAR
  • Voltage and current waveforms
Voltage and current waveforms
  • Voltage and current waveforms
  • True-rms voltage and current
  • Frequency

Voltage, current, and power harmonics
  • Voltage, current, and power harmonics
  • Up to 51st harmonic
  • Total harmonic distortion (THD)
  • Phase angle of individual harmonics
Continuously measure volts and amps on a cycle-by-cycle basis for up to 24 hours
  • Continuously measure volts and amps on a cycle-by-cycle basis for up to 24 hours
  • Use cursors to read time and date of sags and swells
Catch voltage transients and waveform distortion
  • Catch voltage transients and waveform distortion
  • Catch and save up to 40 transients
  • Correlate the cause of transients with time and date stamps

Inrush current up to 500A with supplied current probe
  • Inrush current up to 500A with supplied current probe
  • Use cursors to measure inrush current timing
Connect-and-View scope for quick waveform display
  • Connect-and-View scope for quick waveform display
  • Voltage and current channels
  • 20MHz bandwidth with optional 10:1 voltage probe. 15kHz on current channel with optional current clamp
FlukeView Power Quality Analyzer software
  • FlukeView Power Quality Analyzer software(included)
  • Capture measurement screens for professional-looking reports
  • Log readings to your computer disk drive
  • Works with Windows word processing, spreadsheet and analysis software
  • Windows 95 / 98 / Me / 2000 / NT 4.0

What's Included

  • C120 Hard Case
  • TP1 Flat-tipped Slim-Reach™ Test Probes
  • TP4 4 mm Round Slim-Reach™ Test Probes
  • i400s AC Current Clamp
  • OC4USB Optically Isolated USB Interface Adapter
  • BP120MH Rechargeable NiMH Battery Pack (installed)
  • PM 8907 Line Voltage Adapter/Battery Charger
  • SW43W FlukeView™ Power Quality Analyzer Software and Users Manual on CD-ROM
  • Shielded Banana-to-BNC Adapter
  • Users Manual / Application Guide

Key Features

  • NiMH Battery provides extended operating time of 6.5 hours
  • Combines the most useful capabilities of a power quality analyzer, multimeter and scope
  • Calculates 3-phase power on balanced loads, from a single-phase measurement
  • Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
  • Monitoring functions help track intermittent problems and power system performance
  • Records two selectable parameters for up to 16 days
  • 20 measurement memories to save/recall screens and data with cursor readings
  • FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
  • Measures resistance, diode voltage drop, continuity, and capacitance
  • Users/applications manual and power quality video to help answer tough questions
  • Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
  • 3 year warranty on the Fluke 43B, 1 year on accessories

Specifications

Input Characteristics

Input impedance 1 MΩ, 20 pF
Voltage rating 600V rms, CAT III

V/A/Hz Display

True-rms voltage (ac + dc)
Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V*
Accuracy ±(1% + 10 counts)
True-rms current (ac + dc)
Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA
Accuracy ±(1% + 10 counts)
Frequency
Ranges: 10.0 to 15.0 kHz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
CF Crest factor
Ranges 1.0 - 10.0
Accuracy ±(5% + 1 count)

Power Display

Watts, VA, VAR
1-phase and 3-phase,3 conductor balanced loads
Ranges 250 W - 1.56 GW
Accuracy ±(4% + 4 counts) Fundamental Power
Accuracy ± (2 % + 6 counts) Total Power
PF Power Factor
Range 0 - 1.0
Accuracy ±0.04
DPF Displacement Power Factor, Cos .F
Range 0.25 - 0.9
Accuracy ±0.04
Range 0.90 - 1.0
Accuracy ±0.03
H2 Frequency Fundamental
Ranges 40.0 to 70.0 Hz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2

Harmonics Display

Voltage, Current, Frequency
Ranges: Fundamental to 51st harmonic
Accuracy:
Fundamental VA ±(3% + 2 counts) W ±(5% + 2 counts)
2 to 31st harmonic VA ±(5% +3 counts) W ±(10% +10 counts)
32 to 51st harmonic VA ±(15% +5 counts) W ±(30% +5 counts)
Frequency Fundamental
Ranges 40 Hz to 70 Hz
Accuracy ±0.25 Hz
Phase
Range: V, A (between Fundamental & Harmonics)
Accuracy: ±3° to ±15°
Range W (between Voltage Fundamental & Current Harmonics)
Accuracy ±5° to ±15°
K-factor (Current and Power)
Range: 1.0 to 30.0
Accuracy ±10%
THD Total Harmonic Distortion
Range 0.00 - 99.99
Accuracy: ±(3% + 8 counts)

Sags and Swells

Recording times: 4 min to 16 days (selectable)
Vrms Actual, Vrms max, min(AC + DC)
Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts)
Arms Actual, Arms max, min (AC + DC)
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: ±(2% +10 counts)

Transient Capture

Minimum pulse width: 40 ns
Useful bandwidth input 1 DC to 1 MHz
Number of transients 40
Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference
Reference signal After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting.
Vpeak min, Vpeak max at cursor 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale

R, C, Diode, Continuity

Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ
Resistance accuracy: ±(0.6% + 5 counts)
Capacitance ranges 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
Capacitance accuracy: ±(2% + 10 counts)
Diode Ranges 0 to 3.000 V
Diode voltage:
Accuracy ±(2% + 5 counts)
Continuity: Beeper on at < 30 Ω ± 5 Ω
Max current: 0.5 mA
Temperature °C or °F

Inrush Current

Inrush times 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Cursor readings A peak max at cursor 1 and cursor 2
Accuracy ±5% of full scale
Time between cursors 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)

Temperature (with accessory)

Range -100 °C - 400 °C
Accuracy ±(0.5% + 5 counts)

Scope Display

Measurements dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
Time ranges: 20 ns/div to 60 s/div
Max sampling rate 25 MS/s
Bandwidth
Voltage channel [1] 20 MHz at inputs, 1 MHz with TL24 Leads
Current channel [2] DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp
Coupling: AC, DC (10 Hz - 3 dB)
Vertical sensitivity 5 mV/div to 500V/div
Vertical resolution: 8 bit (256 levels)
Record length: 512 samples per channel
Base ranges 60 S/div to 20 nS/div ± (0.4% + 1 pixel)
Timebase modes Normal, roll, single
Pre-trigger: Up to 10 divisions
Trigger Source Input 1 or Input 2 or automatic selection
Trigger Mode Automatic Connect-and-View™, Free Run, and Single Shot
Connect-and-View™ Advanced automatic triggering that recognizes signal patterns
Automatically adjusts triggering, timebase and amplitude and displays stable pictures

Memories

20 (screens, settings, data)

Recording

Recording times 4 min to 16 days (selectable)
Parameters Choose one or two parameters from one of the groups below
Volts/Ampères/Hertz
Power Watts, VA, VAR, PF, DPF, Frequency
Harmonics, THD, Volts (Fund. & Harmonic), Ampères (F&H) Watts(F&H)
Frequency (H), %(H) of total, Phase(H), KF
Temperature
Resistance Resistance, Diode, Continuity, Capacitance
Scope DC Voltage, DC Current, AC Voltage, AC Current, Frequency,
Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor

Note

*Rated EN 61010-1 600 V CAT III CSA

Environmental Specifications

Operating Temperature

0°C to +50°C

Safety Specifications

Electrical Safety

EN 61010-1 CAT III, 600V. CSA listed

Fluke 43B/003 Specifications

Input Characteristics

Input impedance 1 MΩ, 20 pF
Voltage rating 600V rms, CAT III

V/A/Hz Display

True-rms voltage (ac + dc)
Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V*
Accuracy ±(1% + 10 counts)
True-rms current (ac + dc)
Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA
Accuracy ±(1% + 10 counts)
Frequency
Ranges: 10.0 to 15.0 kHz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
CF Crest factor
Ranges 1.0 - 10.0
Accuracy ±(5% + 1 count)

Power Display

Watts, VA, VAR
1-phase and 3-phase,3 conductor balanced loads
Ranges 250 W - 1.56 GW
Accuracy ±(4% + 4 counts) Fundamental Power
Accuracy ± (2 % + 6 counts) Total Power
PF Power Factor
Range 0 - 1.0
Accuracy ±0.04
DPF Displacement Power Factor, Cos .F
Range 0.25 - 0.9
Accuracy ±0.04
Range 0.90 - 1.0
Accuracy ±0.03
H2 Frequency Fundamental
Ranges 40.0 to 70.0 Hz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2

Harmonics Display

Voltage, Current, Frequency
Ranges: Fundamental to 51st harmonic
Accuracy:
Fundamental VA ±(3% + 2 counts) W ±(5% + 2 counts)
2 to 31st harmonic VA ±(5% +3 counts) W ±(10% +10 counts)
32 to 51st harmonic VA ±(15% +5 counts) W ±(30% +5 counts)
Frequency Fundamental
Ranges 40 Hz to 70 Hz
Accuracy ±0.25 Hz
Phase
Range: V, A (between Fundamental & Harmonics)
Accuracy: ±3° to ±15°
Range W (between Voltage Fundamental & Current Harmonics)
Accuracy ±5° to ±15°
K-factor (Current and Power)
Range: 1.0 to 30.0
Accuracy ±10%
THD Total Harmonic Distortion
Range 0.00 - 99.99
Accuracy: ±(3% + 8 counts)

Sags and Swells

Recording times: 4 min to 16 days (selectable)
Vrms Actual, Vrms max, min(AC + DC)
Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts)
Arms Actual, Arms max, min (AC + DC)
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: ±(2% +10 counts)

Transient Capture

Minimum pulse width: 40 ns
Useful bandwidth input 1 DC to 1 MHz
Number of transients 40
Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference
Reference signal After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting.
Vpeak min, Vpeak max at cursor 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale

R, C, Diode, Continuity

Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ
Resistance accuracy: ±(0.6% + 5 counts)
Capacitance ranges 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
Capacitance accuracy: ±(2% + 10 counts)
Diode Ranges 0 to 3.000 V
Diode voltage:
Accuracy ±(2% + 5 counts)
Continuity: Beeper on at < 30 Ω ± 5 Ω
Max current: 0.5 mA
Temperature °C or °F

Inrush Current

Inrush times 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Cursor readings A peak max at cursor 1 and cursor 2
Accuracy ±5% of full scale
Time between cursors 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)

Temperature (with accessory)

Range -100 °C - 400 °C
Accuracy ±(0.5% + 5 counts)

Scope Display

Measurements dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
Time ranges: 20 ns/div to 60 s/div
Max sampling rate 25 MS/s
Bandwidth
Voltage channel [1] 20 MHz at inputs, 1 MHz with TL24 Leads
Current channel [2] DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp
Coupling: AC, DC (10 Hz - 3 dB)
Vertical sensitivity 5 mV/div to 500V/div
Vertical resolution: 8 bit (256 levels)
Record length: 512 samples per channel
Base ranges 60 S/div to 20 nS/div ± (0.4% + 1 pixel)
Timebase modes Normal, roll, single
Pre-trigger: Up to 10 divisions
Trigger Source Input 1 or Input 2 or automatic selection
Trigger Mode Automatic Connect-and-View™, Free Run, and Single Shot
Connect-and-View™ Advanced automatic triggering that recognizes signal patterns
Automatically adjusts triggering, timebase and amplitude and displays stable pictures

Memories

20 (screens, settings, data)

Recording

Recording times 4 min to 16 days (selectable)
Parameters Choose one or two parameters from one of the groups below
Volts/Ampères/Hertz
Power Watts, VA, VAR, PF, DPF, Frequency
Harmonics, THD, Volts (Fund. & Harmonic), Ampères (F&H) Watts(F&H)
Frequency (H), %(H) of total, Phase(H), KF
Temperature
Resistance Resistance, Diode, Continuity, Capacitance
Scope DC Voltage, DC Current, AC Voltage, AC Current, Frequency,
Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor

Note

*Rated EN 61010-1 600 V CAT III CSA

Environmental Specifications

Operating Temperature

0°C to +50°C

Safety Specifications

Electrical Safety

EN 61010-1 CAT III, 600V. CSA listed
Click here for complete specifications on the Fluke 43B/003

FlukeView Power Quality Analyzer Software (SW43W) offers you simple mouse-controlled tools to work with your Power Quality Analyzer.

The FlukeView software communicates with your Power Quality Analyzer via the optically isolated OC4USB adapter/cable connected to the USB of the PC. The OC4USB driver creates a virtual COM port. FlukeView will handle the USB port as a COM port.

  • Capture measurement screens for professional-looking reports
  • Log readings to your computer disk drive
  • Works with Windows® word processing, spreadsheet and analysis software
  • Windows® 3.1, Windows® 95 and Windows® NT compatible

FlukeView software enables you to read the following types of data from the Power Quality Analyzer into a window on the PC screen:

  • Display Instrument Screens
  • Display Waveforms
  • Display Trend
  • Display Spectrum/Harmonics
  • Display Limits
  • Display Setup
  • Start Logging of Readings
  • Multiple Transfers of Screens/Windows

Note:
The optional RS-232 adapter/cable PM9080 allows you to communicate via a COM port of your PC.

Accessories

Click on a category to view a selection of compatible accessories with the Fluke 43B Power Quality Analyzer.

Fluke i3000s Flex-24 Flexible AC Current Probe, 24 inch length I3000S-FLEX-24 4624
Flexible 24" 3000A AC current probe with BNC terminated lead.
$472.49 USD

was$524.99


Learn More

Fluke i1000s AC Current Clamp I1000S 1820
1000A AC Current Clamp with BNC terminated lead.
$517.49 USD

was$574.99


Learn More

Fluke i6000s Flex-36 AC Current Probe I6000S-FLEX-36 5936
Flexible 36" 6000A AC current probe with BNC terminated lead.
$719.99 USD

was$799.99


Learn More

Fluke i2000 FLEX Flexible AC Current Probe I2000-FLEX 1823
2000A flexible AC current transformer for Fluke power quality analyzers.
$359.99 USD

was$399.99


Learn More

Fluke i6000s Flex-24 AC Current Probe I6000S-FLEX-24 5937
Flexible 24" 6000A AC current probe with BNC terminated lead.
$629.99 USD

was$699.99


Learn More

Fluke 80i-110s AC/DC Current Clamp 80I-110S 1530
100A DC/70A AC current clamp with BNC terminated lead.
$719.99 USD

was$799.99


Learn More

Fluke i400S AC Current Clamp I400S 1825
400A AC current clamp with BNC terminated lead.
$260.99 USD

was$289.99


Learn More

Fluke i200s AC Current Clamp I200S 1555
200A AC current clamp with BNC terminated lead.
$224.99 USD

was$249.99


Learn More

Fluke i3000s AC Current Clamp I3000S 1556
3000A AC current clamp with BNC terminated lead
$562.49 USD

was$624.99


Learn More

$242.99 USD

was$269.99


Learn More

$134.99 USD

was$149.99


Learn More

Fluke AC220 SureGrip Alligator Clips AC220 1400
Designed to improve steadiness with rubber overmolded surfaces and finger-hugging curves.
$44.99 USD

Learn More

Fluke AC285 SureGrip Large Alligator Clip AC285 1403
Large alligator clip for test leads used with Fluke meters.
$24.99 USD

Learn More

Fluke TLK225 SureGrip Master Accessory Kit TLK-225 2032
Kit includes Fluke AC220, AC280, AC283, AC285, TP175, and TL224 all in a 6-Pocket Storage Pouch.
$143.99 USD

was$159.99


Learn More

Fluke BB120 Shielded Banana to Female BNC Adapter BB120 1539
Shielded Banana to Female BNC Adapter for Fluke meters and probes.
$39.99 USD

Learn More

Fluke L210 Probe Light Kit L210 1835
L200 Probe Light and Probe Extenders.
$44.99 USD

Learn More

Fluke C120 Hard Carrying Case C120 1429
For use with the Fluke 120 Series.
$116.99 USD

was$129.99


Learn More



Fluke C550 Premium Tool Bag C550 1447
Tool Bag with steel reinforced frame.
$99.99 USD

Learn More

Fluke TL220 Suregrip Industrial Test Lead Set TL220 1990
Includes Fluke AC220, Fluke TP220, and Fluke TL224.
$79.99 USD

Learn More

Fluke TL221 Suregrip Silicone Test Lead Extension Kit TL221 1992
Test Lead Extension Kit designed to improve steadiness with rubber overmolded surfaces and finger-hugging curves.
$29.99 USD

Learn More

Fluke TL223 Suregrip Electrical Test Lead Set TL223 1994
includes Fluke AC220, TP1, TL224.
$79.99 USD

Learn More

Fluke TL224 SureGrip Silicone Insulated Test Leads TL224 1995
Designed to improve steadiness with rubber overmolded surfaces and finger-hugging curves.
$29.99 USD

Learn More

Fluke TL238 Test Lead Set for High Energy Environment TL238 1996
Designed for high energy environments. Kit includes Fluke TP238, TP280, TL224.
$79.99 USD

Learn More

Fluke TL27 Heavy Duty Test Lead Set TL27 2000
DMM test leads (red, black) with safety shrouded, standard diameter banana plugs.
$34.99 USD

Learn More

Fluke TL71 Premum DMM Test Lead Set TL71 2005
Comfort grip probes with silicone insulated, right-angle test leads.
$29.99 USD

Learn More


Ask a question about the Fluke 43B Power Quality Analyzer:

comments powered by Disqus

Review the Fluke 43B Power Quality Analyzer

" data-description="Popular single phase power quality analyzer designed for simple short-term testing and troubleshooting on electrical devices or panels. Ships complete with a 400A clamp-on current probe.">