The Fluke 54 Series II Digital Datalogging thermometers offers high
accuracy with fast response time to capture your measurement and show
trends.
This Fluke 54 II can log up to 500 points of data to
intermal memory, and has dual inputs, real-time clock captures the
exact time of day of events.
- Relative time clock on MIN, MAX, and AVG provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, and E-types of thermocouples
- Readout in ºC, ºF, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the calibration seal
- Optional
ToolPak accessory allows the thermometer to hang from any metal object
(with the rare earth magnet) or secure around a pipe (with
hook-and-loop straps) for hands-free operation.
- 3 year warranty
The Fluke 53 Series II and 54 Series II include all the features listed above plus:
- Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG.
- Additional thermocouple types R, S, and N (for a total of 7 different types)
- Recall function allows logged data to be easily reviewed on the meter display
- IR
communication port allows data to be exported to optional FlukeView
Forms® Temperature PC software for further analysis and graphing
- Data Logging up to 500 points of data with user adjustable recording interval
| Specifications |
| Temperature accuracy |
| Above -100 °C: |
J, K, T, E, and N-type: ±[0.05% + 0.3°C]*
|
|
R and S-type: ±[0.05% + 0.4°C]* |
| Below -100 °C: |
J, K, E, and N-types: ±[0.20% + 0.3°C]* |
|
T-type: ±[0.50% + 0.3°C] |
|
| Temperature Range |
| J-type: |
-210 °C to 1200 °C |
| K-type: |
-200 °C to 1372 °C |
| T-type: |
-250 °C to 400 °C |
| E-type: |
-150 °C to 1000 °C |
| N-type: |
-200 °C to 1300 °C * |
| R and S-type: |
0 °C to 1767 °C * |
|
| Temperature scale | |
| Applicable standards | |
| Display Resolution |
|
0.1 °C, 0.1 K < 1000 |
|
1°C, 1 K >=1000 |
|
| Note |
| * |
Only the Fluke Models 53 II and 54 II thermometers are capable of measuring N, R, and S-type thermocouples. |
|
| Environmental Specifications |
| Operating Temperature | |
| Storage Temperature | |
| Humidity (Without Condensation) |
|
0% to 90%; 0 °C to 35 °C |
|
0% to 70%; 0 °C to 50 °C |
|
| Safety Specifications |
| Overvoltage category |
|
CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
|
| Agency Approvals | |
| Mechanical & General Specifications |
| Size |
|
173 mm L x 86 mm W x 38 mm |
|
| Weight | |
| Batteries |
|
3 AA batteries; typical 1000-hour life | |